About Us - NAL Passive Safety News - NAL Demonstration Day Customer Login & Register Media Gallery Technical Downloads
 
PDF available for download
View Media Gallery
Powerpoint available for download
View Media Gallery
Cad available for download

The NAL MOBS (Mechanical Only Breakaway System) is a physical termination for NE or LE Passively Safe Columns. It is a minimum option for isolating the electricity supply to a single structure under impact. The systems activation relies on the physical disconnection, on impact of a tethered in-line IP68 Plug and Socket.

The MOBS System is located within an IP67 enclosure which is mounted in the NAL underground STAKKAboxTM Access Chamber. This is a lightweight twin wall structural Access Chamber which is capable of withstanding a 40 tonne vertical load without the need for a concrete surround for support. A galvanised steel eyebolt is provided to enable a secure fixing point within the STAKKAboxTM Access Chamber. The STAKKAboxTM Access Chamber is normally located within 3-5 metres from the structure it is protecting.

The MOBS unit is assembled to your requirements and can accommodate a range of cable sizes from 6mm-25mm 4 core SWA cables. Each unit is provided with 5 metres of flex cable as standard, complete with one IP68 in-line Plug and Sockets. These are mounted and tensioned within the Passively Safe Structure, just below ground level. On impact if the column detaches from it’s base the tensioned in-line Plug and Socket will separate, leaving the detached structure voltage free.

Important Note:
This system does not provide an automatic electrical disconnection. It relies on tension being applied to a tethered plug and socket, which will pull apart if the column detaches under impact.
Please note:
If column fails to detach, the plug and socket will not disconnect!
FOR ZERO VOLT GUARANTEED DISCONNECTION PLEASE REFER TO OUR ABOVE OR
BELOW GROUND SIS- SAFETY ISOLATION SYSTEM